2. Adjust the start and stop position of the cam divider;
3. Replace the vent cap of the cam divider;
4. Replace the lubricating oil of the cam divider;
Today a friend asked about the cam divider and sent me a picture as follows:
The force shaft of the divider in the picture is connected to the power source through a connecting rod. The fracture of the input shaft has a lot to do with the force mode. It is recommended that customers measure the horizontality of the connecting rod. When the input shaft of the divider and the connecting rod cannot remain horizontal, the shaft will easily break.
This type of problem has been encountered many times before, usually in old equipment or when debugging new equipment. Today's customer's input shaft was broken. For DS-type splitters, the input shaft must be subjected to force to ensure horizontality, and the output shaft must be subjected to force to ensure verticality. There are also cases where the output shaft is broken.
When the internal bearing of the divider is not broken but the input shaft or output shaft is broken, it is most likely caused by unreasonable force. When repairing old equipment or installing and debugging new equipment, be sure to measure the horizontality and verticality.
Regarding questions about cam dividers, LVNCAM cam dividers from LVN Automation welcomes everyone to communicate and learn together.
related articles